In this paper, we analyzed the RF-EMF measurement results of the high-occupancy facilities.
From 2023 to 2024, we selected 995 High-occupancy Facilities. The results of the RF-EMF measurement were conducted in parallel with two devices.
First, RF-EMF measurement was selected the points where RF-EMF exposure was expected to be high and measured for 1 to 6 minutes at the heights of 1.1m, 1.5m, and 1.7m, and calculated the maximum measurements using Narda SRM-3006 devices.
Inaddition, we measured the RF-EMF according to relevant standards at six-minute intervals for 24 hours during 3-month and calculated as the RMS average.
According to the measurement results, the RF-EMF of the High-occupancy facilities was found to be very low, up to 2.41 V/m, compared to the ICNIRP guidelines. There were no cases of RF-EMF exceeding the human protection standards.
To alleviate public anxiety regarding RF-EMF exposure, it seems necessary to expand RF-EMF measurement services to allow everyone to experience the results firsthand by disclosing the measurement results of various facilities.